# Concept Group LLC: Insulon® Vacuum Jacketed Products > Proprietary, ultra\-high performance vacuum insulation for applications from \-270°C to 815°C and higher\. Discover Insulon® Technology\. Generated by Yoast SEO v28.4, this is an llms.txt file, meant for consumption by LLMs. ## Pages - [About Concept Group LLC](https://conceptgroupllc.com/about/) - [Contact Us](https://conceptgroupllc.com/contact/) - [General Terms and Conditions of Sale of Goods](https://conceptgroupllc.com/terms-and-conditions-of-sale-of-goods/) - [Privacy Policy](https://conceptgroupllc.com/privacy-policy/) - [Shop Insulon® Products](https://conceptgroupllc.com/shop/) - [Insulon® Vacuum Jacketed Hoses for Critical Thermal Fluid Management](https://conceptgroupllc.com/products/insulon-vacuum-jacketed-hose/) - [Product Comparison \& Specifications](https://conceptgroupllc.com/products/insulon-vacuum-jacketed-hose/product-comparison-specifications/) - [Insulon® Vacuum Insulated Heat Exchangers](https://conceptgroupllc.com/products/insulon-vacuum-insulated-heat-exchangers/) - [Insulon® Vacuum Jacketed Fluoropolymer \(PTFE, PFA, FEP\) Tubing](https://conceptgroupllc.com/products/ptfe-pfa-tubing-with-insulon-vacuum-jacketed-hose/) ## Posts - [Pressure Class vs\. MAWP: How Temperature Determines a Hose’s Pressure Limit](https://conceptgroupllc.com/pressure-class-vs-mawp-how-temperature-determines-a-hoses-pressure-limit/) - [Insulon® smooth\-bore options for thermal process fluid transfer](https://conceptgroupllc.com/insulon-smooth-bore-options-for-thermal-process-fluid-transfer/) ## FAQs - [Does Standard or MLI affect the pressure rating?](https://conceptgroupllc.com/faq/does-standard-or-mli-affect-the-pressure-rating/) - [Are end fittings already attached to Insulon® Hoses?](https://conceptgroupllc.com/faq/are-end-fittings-already-attached/) - [Who manufactures Insulon® Vacuum Jacketed Hose?](https://conceptgroupllc.com/faq/who-manufactures-insulon-vacuum-jacketed-hose/) - [Can Insulon® vacuum jacketed hoses be ordered in longer sections and cut to length?](https://conceptgroupllc.com/faq/can-vacuum-jacketed-hoses-be-ordered-in-longer-sections-and-cut-to-length/) - [Does adding an outer braid to Insulon® Vacuum Jacketed Hose affect the pressure rating?](https://conceptgroupllc.com/faq/does-adding-an-outer-braid-to-insulon-vacuum-jacketed-hose-affect-the-pressure-rating/) ## Products - [Insulon® Vacuum Jacketed Hose, High Pressure, MLI, 1/4" ID](https://conceptgroupllc.com/shop/insulon-vacuum-jacketed-hoses/insulon-vacuum-jacketed-hose-high-pressure-with-mli-1-4-id/): \1/4" ID vacuum jacketed hose engineered with Concept Group's proprietary Insulon® technology\.\\\MLI \(multi\-layer insulation\) blocks convection, conduction, and radiation heat transfer for maximum thermal insulation performance\. Recommended for cryogens at the lowest temperatures \(LHe, LH2\) and continuous cryogenic flow where radiation heat gain is significant\.\\Available in lengths up to 65 feet\.\\Rated operating temperature: \-270°C to 815°C \(\-454°F to 1,500°F\)\.\\High Pressure: rated to 750 psi at room temperature \(≤100°F / 38°C\)\. MAWP decreases at elevated fluid temperatures; see derating table in product description\.\\Wetted surface material: 316/316L stainless steel\.\\All Insulon® hoses ship with tube stub ends as default\. Option to add end fittings; see below\.\\ - [Insulon® Vacuum Jacketed Hose, High Pressure, MLI, 1/4" ID, with Outer Braid](https://conceptgroupllc.com/shop/insulon-vacuum-jacketed-hoses/outer-braid/insulon-vacuum-jacketed-hose-high-pressure-with-mli-1-4-id-outer-braid/): \1/4" ID vacuum jacketed hose with outer braid, engineered with Concept Group's proprietary Insulon® technology\.\\\MLI \(multi\-layer insulation\) blocks convection, conduction, and radiation heat transfer for maximum thermal insulation performance\. Recommended for cryogens at the lowest temperatures \(LHe, LH2\) and continuous cryogenic flow where radiation heat gain is significant\.\\Available in lengths up to 65 feet\.\\Rated operating temperature: \-270°C to 815°C \(\-454°F to 1,500°F\)\.\\High Pressure: rated to 750 psi at room temperature \(≤100°F / 38°C\)\. MAWP decreases at elevated fluid temperatures; see derating table in product description\.\\Wetted surface material: 316/316L stainless steel\.\\Outer braid adds abrasion resistance for rugged handling and mobile transfer applications\.\\All Insulon® hoses ship with tube stub ends as default\. Option to add end fittings; see below\.\\ - [Insulon® Vacuum Jacketed Hose, High Pressure, MLI, 1/2" ID, with Outer Braid](https://conceptgroupllc.com/shop/insulon-vacuum-jacketed-hoses/outer-braid/insulon-vacuum-jacketed-hose-high-pressure-with-mli-1-2-id-outer-braid/): \1/2" ID vacuum jacketed hose with outer braid, engineered with Concept Group's proprietary Insulon® technology\.\\\MLI \(multi\-layer insulation\) blocks convection, conduction, and radiation heat transfer for maximum thermal insulation performance\. Recommended for cryogens at the lowest temperatures \(LHe, LH2\) and continuous cryogenic flow where radiation heat gain is significant\.\\Available in lengths up to 65 feet\.\\Rated operating temperature: \-270°C to 815°C \(\-454°F to 1,500°F\)\.\\High Pressure: rated to 750 psi at room temperature \(≤100°F / 38°C\)\. MAWP decreases at elevated fluid temperatures; see derating table in product description\.\\Wetted surface material: 316/316L stainless steel\.\\Outer braid adds abrasion resistance for rugged handling and mobile transfer applications\.\\All Insulon® hoses ship with tube stub ends as default\. Option to add end fittings; see below\.\\ - [Insulon® Vacuum Jacketed Hose, Low Pressure, Standard, 1" ID](https://conceptgroupllc.com/shop/insulon-vacuum-jacketed-hoses/insulon-hose-lp-1-in/): \1" ID vacuum jacketed hose engineered with Concept Group's proprietary Insulon® technology\.\\\Standard vacuum insulation blocks convection and conduction heat transfer\. Compact, lightweight, and flexible; the most space\-efficient option in the Insulon® hose product line\.\\Available in lengths up to 65 feet\.\\Rated operating temperature: \-270°C to 815°C \(\-454°F to 1,500°F\)\.\\Low Pressure: rated to 43 psi at room temperature \(≤100°F / 38°C\)\. MAWP decreases at elevated fluid temperatures; see derating table in product description\.\\Wetted surface material: 316/316L stainless steel\.\\All Insulon® hoses ship with tube stub ends as default\. Option to add end fittings; see below\.\\ - [Insulon® Vacuum Jacketed Hose, Low Pressure, Standard, 1/2" ID](https://conceptgroupllc.com/shop/insulon-vacuum-jacketed-hoses/insulon-hose-lp-1-2-in/): \1/2" ID vacuum jacketed hose engineered with Concept Group's proprietary Insulon® technology\.\\\Standard vacuum insulation blocks convection and conduction heat transfer\. Compact, lightweight, and flexible; the most space\-efficient option in the Insulon® hose product line\.\\Available in lengths up to 65 feet\.\\Rated operating temperature: \-270°C to 815°C \(\-454°F to 1,500°F\)\.\\Low Pressure: rated to 72 psi at room temperature \(≤100°F / 38°C\)\. MAWP decreases at elevated fluid temperatures; see derating table in product description\.\\Wetted surface material: 316/316L stainless steel\.\\All Insulon® hoses ship with tube stub ends as default\. Option to add end fittings; see below\.\\ ## Glossary Terms - [What is a vacuum jacketed hose?](https://conceptgroupllc.com/glossary/what-is-a-vacuum-jacketed-hose/) - [What is a phase change material?](https://conceptgroupllc.com/glossary/what-is-a-phase-change-material/) - [What is a cleanroom?](https://conceptgroupllc.com/glossary/what-is-a-cleanroom/) - [What is a wire harness?](https://conceptgroupllc.com/glossary/what-is-a-wire-harness/) - [What is corrosion under insulation?](https://conceptgroupllc.com/glossary/what-is-corrosion-under-insulation/) ## Categories - [Vacuum Insulation](https://conceptgroupllc.com/vacuum-insulation/) - [Vacuum Jacketed Hoses](https://conceptgroupllc.com/vacuum-jacketed-hoses/) - [High Performance Thermal Insulation](https://conceptgroupllc.com/high-performance-thermal-insulation/) - [Industrial Manufacturing](https://conceptgroupllc.com/industrial-manufacturing/) - [Cleanroom Manufacturing](https://conceptgroupllc.com/cleanroom-manufacturing/) ## Tags - [Hose Insulation](https://conceptgroupllc.com/tag/hose-insulation/) - [High Temperature Insulation](https://conceptgroupllc.com/tag/high-temp/) - [Cryogenic Insulation](https://conceptgroupllc.com/tag/cryogenic/) - [Thermal Management](https://conceptgroupllc.com/tag/thermal-management/) - [Chiller Systems](https://conceptgroupllc.com/tag/chiller-systems/) ## Product brands - [Insulon®](https://conceptgroupllc.com/brand/insulon/) ## Product categories - [Insulon® Vacuum Jacketed Hoses](https://conceptgroupllc.com/product-category/insulon-vacuum-jacketed-hoses/) - [End Fittings](https://conceptgroupllc.com/product-category/end-fittings/) - [Insulon® Vacuum Jacketed Hoses with Outer Braid](https://conceptgroupllc.com/product-category/insulon-vacuum-jacketed-hoses/outer-braid/) - [Insulon® Vacuum Jacketed PTFE/PFA Tubing](https://conceptgroupllc.com/product-category/ptfe-pfa-tubing/) - [Insulon® Safety Nozzle Guards](https://conceptgroupllc.com/product-category/hot-air-tools/) ## Categories - [Thermal Engineering](https://conceptgroupllc.com/glossary-cat/thermal-engineering/) - [Heat Transfer](https://conceptgroupllc.com/glossary-cat/heat-transfer/) - [Cryogenics](https://conceptgroupllc.com/glossary-cat/cryogenics/) - [Manufacturing](https://conceptgroupllc.com/glossary-cat/manufacturing/) ## Optional - [Sitemap index](https://conceptgroupllc.com/sitemap_index.xml)